Iei-integration AFL2-12A-D525 Manuale Utente Pagina 176

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 180
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 175
AFL2-12A-D525 Series Panel PC
Page 176
NOTE:
When exiting a program it is necessary to disable the Watchdog Timer,
otherwise the system resets.
Example program:
; INITIAL TIMER PERIOD COUNTER
;
W_LOOP:
MOV AX, 6F02H ;setting the time-out value
MOV BX, 05 ;time-out value is 5 seconds
INT 15H
;
; ADD THE APPLICATION PROGRAM HERE
;
CMP EXIT_AP, 1 ;is the application over?
JNE W_LOOP ;No, restart the application
MOV AX, 6F02H ;disable Watchdog Timer
MOV BX, 0 ;
INT 15H
;
; EXIT ;