NANO-LX EPIC SBC
Step 4: Use the arrow keys to highlight Create RAID0 Striping for Performance and
press E
NTER. A flashing ‘S’ appears at the Drive Menu where the member
drives to be included in the RAID0 array can be chosen.
Step 5: Use the space bar to select members of the RAID0 RAID configuration. The
flashing cursor changes to a lower case ‘s’ once any of the connected disk
drives has been selected. Follow the same method to select another member
drive.
Step 6: The Create RAID0(Y/N) confirm box appears. Press Y.
Step 7: Enter a nickname for the created array. Upper and lower case alphabetic,
numeric, space, and underscore characters are all applicable for naming an
array.
Step 8: Once an array is successfully created, it will be seen in the list of configured
arrays.Step 0: